1Z0-066 Valid Test Collection Free & Reliable Exam 1Z0-066 Simulator Free - Test 1Z0-066 Duration - Omgzlook

Which kind of 1Z0-066 Valid Test Collection Free certificate is most authorized, efficient and useful? We recommend you the 1Z0-066 Valid Test Collection Free certificate because it can prove that you are competent in some area and boost outstanding abilities. If you buy our 1Z0-066 Valid Test Collection Free study materials you will pass the test smoothly and easily. We boost professional expert team to organize and compile the 1Z0-066 Valid Test Collection Free training guide diligently and provide the great service. A lot of people have given up when they are preparing for the 1Z0-066 Valid Test Collection Free exam. However, we need to realize that the genius only means hard-working all one’s life. More importantly, if you take our products into consideration, our 1Z0-066 Valid Test Collection Free study materials will bring a good academic outcome for you.

Oracle Database 12c 1Z0-066 Our research materials have many advantages.

So if you get any questions of our 1Z0-066 - Oracle Database 12c: Data Guard Administrator Valid Test Collection Free learning guide, please get us informed. You really can't find a more cost-effective product than Reliable Vce 1Z0-066 Test Simulator learning quiz! Our company wants more people to be able to use our products.

Passing the 1Z0-066 Valid Test Collection Free exam has never been so efficient or easy when getting help from our 1Z0-066 Valid Test Collection Free training materials. This way is not only financially accessible, but time-saving and comprehensive to deal with the important questions emerging in the real exam. All exams from different suppliers will be easy to handle.

Oracle 1Z0-066 Valid Test Collection Free - The reality is often cruel.

We attract customers by our fabulous 1Z0-066 Valid Test Collection Free certification material and high pass rate, which are the most powerful evidence to show our strength. We are so proud to tell you that according to the statistics from our customers’ feedback, the pass rate among our customers who prepared for the exam with our 1Z0-066 Valid Test Collection Free test guide have reached as high as 99%, which definitely ranks the top among our peers. Hence one can see that the Oracle Database 12c: Data Guard Administrator learn tool compiled by our company are definitely the best choice for you.

Imagine, if you're using a 1Z0-066 Valid Test Collection Free practice materials, always appear this or that grammar, spelling errors, such as this will not only greatly affect your mood, but also restricted your learning efficiency. Therefore, good typesetting is essential for a product, especially education products, and the 1Z0-066 Valid Test Collection Free test material can avoid these risks very well.

1Z0-066 PDF DEMO:

QUESTION NO: 1
You created a physical standby database PRODSBY1 from the primary database PROD using SQL and RMAN Which two are prerequisites for creating a Data Guard Broker configuration to manage these databases?
A. The standby database must have supplemental logging enabled.
B. The primary database must have FORCE LOGGING enabled
C. The DG_BROKER_START parameter must be set to TRUE for both database
instances.
D. The primary database must have supplemental logging enabled.
E. A local net service name to enable connectivity to the PRODSBY1 database instance must be defined on the primary database host.
Answer: B,C

QUESTION NO: 2
A customer has these requirements for their potential Data Guard implementation:
1. Zero data loss must still be guaranteed through the loss of any one configuration component.
2 The primary database must be protected against a regional disaster
3 . Performance overheads on the primary should be minimized as much as possible given these requirements.
4. Downtime on the primary database for any reason must be kept to a minimum.
Components referred to in the broker commands are:
Which Data Guard broker commands are needed to implement these requirements?
A. EDIT DATABASE prima SET PROPERY REDOROUTES=' (LOCAL: physt1,
FASTSYNC)'; EDIT DATABASE prima SET PROPERY REDOROUTES=' (LOCAL: fs1
SYNC)'; EDIT FAR_SYNC fs1 SET PROPERTY REDORUOTES=' (pnma: physt2 SYNC)';
EDIT CONFIGURATION SET PROTECTION MODE AS MAXAVAILABILITY
B. EDIT DATABASE prima SET PROPERY REDOROUTES=' (LOCAL: fs1 ASYNC)'; EDIT
FAR_SYNC fs1 SET PROPERTY REDORUOTES=' (prima physt FASTSYNC)'; EDIT
CONFIGURATION SET PROTECTION MODE AS MAXPROTECTION
C. EDIT DATABASE prima SET PROPERY REDOROUTES' (LOCAL: fs1 SYNC)'; EDIT
FAR_SYNCfs1 SET PROPERTY REDORUOTES=' (prima physt ASYNC)'; EDIT
CONFIGURATION SET PROTECTION MODE AS MAXAVAILABILITY;
D. EDIT DATABASE prima SET PROPERY REDOROUTES=' (LOCAL: physt1,
FASTSYNC)'; EDIT DATABASE prima SET PROPERY REDOROUTES= (LOCAL: fs1.
FASTSYNC)'; EDIT FAR_SYNC fs1 SET PROPERTY REDORUOTES=' (prima: physt2
ASYNC)'; EDIT CONFIGURATION SET PROTECTION MODE AS MAXAVAILABILITY;
Answer: A

QUESTION NO: 3
Examine the Data Guard configuration:
Configuration Status: SUCCESS
Which two are true?
A. The observer must run on host ol5.example com and is currently not running.
B. The observer will reinstate Sheep automatically after a failover, if required.
C. The observer will mark another standby database as the failover target if the original failover target becomes unavailable.
D. The observer will detect if the primary database is unable to accept new connections
E. The former primary database will not be reinstated automatically alter a failover.
Answer: B,E

QUESTION NO: 4
You are required to change the Data Guard Configuration protection mode from
MAXPERFORMANCE to MAXAVAJLABILITY using Enterprise Manager Cloud Control
Which two are true about this change?
A. If the primary database cannot write its redo to at least one synchronized standby database, then the protection level remains unchanged.
B. The primary database instance will remain up and running, if it cannot write redo to at least one synchronized standby database.
C. Transactions will not commit until all redo data needed to recover those transactions are written to the online redo log, and to the standby redo log on at least one synchronizes standby database.
D. Fast start failover can be enabled when making the chance.
E. Real time apply will be automatically turned on.
Answer: B,C

QUESTION NO: 5
Which two Data Guard features require the use of flashback database by the broker?
A. Read-Mostly physical standby implementations
B. Far Sync Instances
C. Fast-Start Failover
D. Real Time Query
E. Snapshot Standby databases
Answer: C,E

All in all, high efficiency of Palo Alto Networks PCNSE exam material is the reason for your selection. We employ the senior lecturers and authorized authors who have published the articles about the test to compile and organize the Network Appliance NS0-528 prep guide dump. To help you get to know the exam questions and knowledge of the SAP C-THR95-2405 practice exam successfully and smoothly, our experts just pick up the necessary and essential content in to our SAP C-THR95-2405 test guide with unequivocal content rather than trivia knowledge that exam do not test at all. EMC D-XTR-DS-A-24 - You will find that learning is becoming interesting and easy. Many exam candidates ascribe their success to our SAP C_BW4H_2404 real questions and become our regular customers eventually.

Updated: May 28, 2022