350-022 Pdf Dumps - Cisco New CCIE Written, Service Provider: DSL Test Review - Omgzlook

Our test engine has been introduced for the preparation of 350-022 Pdf Dumps practice test and bring great convenience for most IT workers. It will make you feel the atmosphere of the 350-022 Pdf Dumps actual test and remark the mistakes when you practice the exam questions. We strongly recommend that you should prepare your 350-022 Pdf Dumps exam pdf with our test engine before taking real exam. As for the 350-022 Pdf Dumps study materials themselves, they boost multiple functions to assist the learners to learn the 350-022 Pdf Dumps learning dumps efficiently from different angles. For example, the function to stimulate the exam can help the exam candidates be familiar with the atmosphere and the pace of the real 350-022 Pdf Dumps exam and avoid some unexpected problem occur such as the clients answer the questions in a slow speed and with a very anxious mood which is caused by the reason of lacking confidence. You can copy to your mobile, Ipad or others.

CCIE 350-022 Your life will be even more exciting.

Once the user has used our 350-022 - CCIE Written, Service Provider: DSL Pdf Dumps test prep for a mock exercise, the product's system automatically remembers and analyzes all the user's actual operations. The price of our 350-022 Authorized Certification learning guide is among the range which you can afford and after you use our 350-022 Authorized Certification study materials you will certainly feel that the value of the 350-022 Authorized Certification exam questions far exceed the amount of the money you pay for the pass rate of our practice quiz is 98% to 100% which is unmarched in the market. Choosing our 350-022 Authorized Certification study guide equals choosing the success and the perfect service.

In the process of using the CCIE Written, Service Provider: DSL study training dumps, once users have any questions about our study materials, the user can directly by E-mail us, our products have a dedicated customer service staff to answer for the user, they are 24 hours service for you, we are very welcome to contact us by E-mail and put forward valuable opinion for us. Our 350-022 Pdf Dumps latest questions already have many different kinds of learning materials, users may be confused about the choice, what is the most suitable 350-022 Pdf Dumps test guide? Believe that users will get the most satisfactory answer after consultation. Our online service staff is professionally trained, and users' needs about 350-022 Pdf Dumps test guide can be clearly understood by them.

Cisco 350-022 Pdf Dumps - Our reputation is really good.

Our 350-022 Pdf Dumps exam quiz is unlike other exam materials that are available on the market, our 350-022 Pdf Dumps study dumps specially proposed different versions to allow you to learn not only on paper, but also to use mobile phones to learn. This greatly improves the students' availability of fragmented time. So you can achieve your 350-022 Pdf Dumps certification easily without disrupting your daily routine. And we will give you 100% success guaranteed on the 350-022 Pdf Dumps training guide.

In short, you will find the convenience and practicality of our 350-022 Pdf Dumps quiz guide in the process of learning. We will also continue to innovate and improve functions to provide you with better services.

350-022 PDF DEMO:

QUESTION NO: 1
What effect do load coils in a telephone line have on DSL service?
A.Load coils cause low trained rates for ADSL (CAP or DMT), but do not degrade SDSL, SHDSL, or IDSL transmission.
B.Load coils in the telephone line can prevent any DSL modem from training up to an ATU-C port.
C.Load coils cause low upstream rates, but do not degrade downstream rates.
D.Load coils cause low downstream rates, but do not degrade upstream rates.
E.Load coils cause low trained rates for SDSL, SHDSL, or IDSL, but do not degrade ADSL (CAP or DMT) transmission.
Correct:B

QUESTION NO: 2
The following are wire sizes used in telephone company cables. Which will allow the greatest
"reach" (distance) in DSL service?
A.24 AWG (0.5 mm)
B.26 AWG (0.4 mm)
C.A line that is 50% of #24 (0.5mm) and 50 % of #26 (0.4mm).
D.None of the above will allow enough reach for DSL service.
Correct:A

QUESTION NO: 3
A DSL customer has subscribed to a service that provides 2 mbps downstream and 256 kbps upstream. The cable length is 10 kft (3 km). The customer reports that file transfers on the DSL line seem slower than normal in recent days. After reviewing the DSL profile parameters for the
DSL port, and the actual status of the line, what is the possible reason why the subscriber's data rates are slower than usual?DSLAM#show dsl int atm 1/1DMT profile parametersMaximum
Bitrates:Interleave Path: downstream: 2048 kb/s, upstream: 256 kb/sFast Path: downstream: 0 kb/s, upstream: 0 kb/sMinimum Bitrates:Interleave Path: downstream: 0 kb/s, upstream: 0 kb/sFast Path: downstream: 0 kb/s, upstream: 0 kb/sMargin: downstream: 6 dB, upstream: 6 dBInterleaving Delay: downstream: 16000 usecs, upstream: 16000 usecsCheck Bytes
(FEC):Interleave Path: downstream: 16, upstream: 16Fast Path: downstream: 0, upstream: 0R-S
Codeword Size: downstream: auto, upstream: autoTrellis Coding: DisabledOverhead Framing:
Mode 3Operating Mode: AutomaticTraining Mode: QuickMinrate blocking: DisabledSNR
Monitoring: DisabledStatus:Bitrates:Interleave Path: downstream: 640 kb/s, upstream: 256 kb/sFast Path: downstream: 0 kb/s, upstream: 0 kb/sMargin: downstream: 6 dB, upstream: 9 dBAttenuation: downstream: 45 dB, upstream: 31 dBInterleave Delay: downstream: 16000 usecs, upstream: 16000 usecTransmit Power: downstream: 19.4 dB, upstream: 12.0 dBCheck Bytes
(FEC):Interleave Path: downstream: 16, upstream: 16Fast Path: downstream: 0, upstream: 0R-S
Codeword Size: downstream: 1, upstream: 8Trellis Coding: Not In UseOverhead Framing: Mode
3Line Fault: NONEOperating Mode: ITU G dmt Issue 1Line Type: Interleaved Only
A.The signal-to-noise margin on the line will not allow downstream DSL rates faster than 640 kbps. If the subscriber's service was in fact faster at some time, then something has changed in the line characteristics or noise spectrum.
B.The subscriber is provisioned for 640 kbps downstream, and the service appears to be working normally. The problem is apparently not related to the DSL (physical layer) part of the service.
C.The service is running in G.DMT, and 640 kbps is normal for the subscriber's cable length. Change the mode to ANSI T1.413 for faster rates.
D.The DSL profile is set for 16 milliseconds interleave delay. Change the interleave delay to 0, or change the profile to fastpath for faster line rates.
Correct:A

QUESTION NO: 4
What is the effect of changing DMT interleaved delay from 16 milliseconds to 2 milliseconds?
A.Fewer ATM PVCs can be provisioned on the DSL line.
B.Latency is reduced, but error correction effectiveness may also be reduced.
C.Latency remains the same, but faster error correction occurs.
D.Latency remains the same, but throughput is increased.
Correct:B

QUESTION NO: 5
MPLS does not support:
A.Multicast
B.OSPF
C.BGP
D.Multicast and OSPF
Correct:A

We are convinced that our Fortinet NSE5_FSM-6.3 exam questions can help you gain the desired social status and thus embrace success. In such a way, you can confirm that you get the convenience and fast from our Microsoft PL-900-KR study guide. The Palo Alto Networks PCNSE question dumps produced by our company, is helpful for our customers to pass their exams and get the Palo Alto Networks PCNSE certification within several days. SAP C_THR88_2405 - According to the survey, the average pass rate of our candidates has reached 99%. Our Network Appliance NS0-700 learning questions engage our working staff in understanding customers’ diverse and evolving expectations and incorporate that understanding into our strategies, thus you can 100% trust our Network Appliance NS0-700 exam engine.