AZ-220 Latest Real Test Questions & Microsoft Azure IoT Developer Latest Test Blueprint - Omgzlook

They are very practical and they have online error correction and other functions. The characteristic that three versions of AZ-220 Latest Real Test Questions exam torrent all have is that they have no limit of the number of users, so you don’t encounter failures anytime you want to learn our AZ-220 Latest Real Test Questions quiz guide. The three different versions can help customers solve any questions and meet their all needs. Our AZ-220 Latest Real Test Questions exam simulation is a great tool to improve our competitiveness. After we use our AZ-220 Latest Real Test Questions study materials, we can get the AZ-220 Latest Real Test Questions certification faster. Omgzlook can satisfy the fundamental demands of candidates with concise layout and illegible outline of our AZ-220 Latest Real Test Questions exam questions.

Microsoft Certified: Azure IoT Developer Specialty AZ-220 We will never neglect any user.

Our company is open-handed to offer benefits at intervals, with AZ-220 - Microsoft Azure IoT Developer Latest Real Test Questions learning questions priced with reasonable prices. Test AZ-220 Labs training guide’s powerful network and 24-hour online staff can meet your needs. First of all, we can guarantee that you will not encounter any obstacles in the payment process.

They are unsuspecting experts who you can count on. Without unintelligible content within our AZ-220 Latest Real Test Questions study tool, all questions of the exam are based on their professional experience in this industry. Besides, they made three versions for your reference, the PDF, APP and Online software version.

Microsoft AZ-220 Latest Real Test Questions - Cease to struggle and you cease to live.

Our AZ-220 Latest Real Test Questions exam prep will give you a complete after-sales experience. You can consult online no matter what problems you encounter. You can get help anywhere, anytime in our AZ-220 Latest Real Test Questions test material. AZ-220 Latest Real Test Questions test questions have very high quality services in addition to their high quality and efficiency. If you use AZ-220 Latest Real Test Questions test material, you will have a very enjoyable experience while improving your ability. We have always advocated customer first. If you use our learning materials to achieve your goals, we will be honored. AZ-220 Latest Real Test Questions exam prep look forward to meeting you.

Our ability of improvement is stronger than others. New trial might change your life greatly.

AZ-220 PDF DEMO:

QUESTION NO: 1
Your company is creating a new camera security system that will use Azure IoT Hub.
You plan to use an Azure IoT Edge device that will run Ubuntu Server 18.04.
You need to configure the IoT Edge device.
Which three actions should you perform in sequence? To answer, move the appropriate actions from the list of actions to the answer area and arrange them in the correct order.
Answer:
Explanation:
Step 1: Run the following commands
Install the container runtime.
Azure IoT Edge relies on an OCI-compatible container runtime. For production scenarios, we recommended that you use the Moby-based engine provided below. The Moby engine is the only container engine officially supported with Azure IoT Edge. Docker CE/EE container images are compatible with the Moby runtime.
Install the Moby engine.
sudo apt-get install moby-engine
Install the Moby command-line interface (CLI). The CLI is useful for development but optional for production deployments.
sudo apt-get install moby-cli
Install the security daemon. The package is installed at /etc/iotedge/.
sudo apt-get install iotedge
Step 2: From IotHub,create an IoT Edge device registry entry.
Note: In your IoT Hub in the Azure portal, IoT Edge devices are created and managed separately from
IOT devices that are not edge enabled.
Sign in to the Azure portal and navigate to your IoT hub.
In the left pane, select IoT Edge from the menu.
Select Add an IoT Edge device.
Provide a descriptive device ID. Use the default settings to auto-generate authentication keys and connect the new device to your hub.
Select Save.
Retrieve the connection string in the Azure portal
1. When you're ready to set up your device, you need the connection string that links your physical device with its identity in the IoT hub.
2. From the IoT Edge page in the portal, click on the device ID from the list of IoT Edge devices.
3. Copy the value of either Primary Connection String or Secondary Connection String.
Step 3: Add the connection string to..
To manually provision a device, you need to provide it with a device connection string that you can create by registering a new device in your IoT hub.
Open the configuration file.
sudo nano /etc/iotedge/config.yaml
Find the provisioning configurations of the file and uncomment the Manual provisioning configuration section. Update the value of device_connection_string with the connection string from your IoT Edge device.
Save and close the file.
After entering the provisioning information in the configuration file, restart the daemon:
sudosystemctl restart iotedge
Reference:
https://docs.microsoft.com/en-us/azure/iot-edge/how-to-install-iot-edge-linux

QUESTION NO: 2
You have an Azure IoT hub that is being taken from prototype to production.
You plan to connect IoT devices to the IoT hub. The devices have hardware security modules (HSMs).
You need to use the most secure authentication method between the devices and the IoT hub.
Company policy prohibits the use of internally generated certificates.
Which authentication method should you use?
A. a symmetric key
B. An X.509 certificate signed by a root certification authority (CA).
C. an X.509 self-signed certificate
D. a certificate thumbprint
Answer: B
Explanation:
Purchase X.509 certificates from a root certificate authority (CA). This method is recommended for production environments.
The hardware security module, or HSM, is used for secure, hardware-based storage of device secrets, and is the most secure form of secret storage. Both X.509 certificates and SAS tokens can be stored in the HSM Reference:
https://docs.microsoft.com/en-us/azure/iot-dps/concepts-security

QUESTION NO: 3
You have an Azure IoT solution that includes an Azure IoT hub.
You receive a root certification authority (CA) certificate from the security department at your company.
You need to configure the IoT hub to use the root CA certificate.
Which four actions should you perform in sequence? To answer, move the appropriate actions from the list of actions to the answer area and arrange them in the correct order.
Answer:
Reference:
https://docs.microsoft.com/bs-latn-ba/azure/iot-hub/iot-hub-security-x509-get-started

QUESTION NO: 4
You have an instance of Azure Time Series Insights and an Azure IoT hub that receives streaming telemetry from IoT devices.
You need to configure Time Series Insights to receive telemetry from the devices.
Which three actions should you perform in sequence? To answer, move the appropriate actions from the list of actions to the answer area and arrange them in the correct order.
Answer:
Explanation:
Step 1: Create a dedicated consumer group..
Add a consumer group to your IoT hub.
Applications use consumer groups to pull data from Azure IoT Hub. To reliably read data from your
IoT hub, provide a dedicated consumer group that's used only by this Time Series Insights environment.
Step 2: Add a new Time Series Insights event source.
Add a new event source
Sign in to the Azure portal.
In the left menu, select All resources. Select your Time Series Insights environment.
Under Settings, select Event Sources, and then select Add.
In the New event source pane, for Event source name, enter a name that's unique to this Time Series
Insights environment. For example, enter event-stream.
Step 3: Configure the Time Series event source to connect to an existing IOT hub Step 4: For Source, select IoT Hub.
Step 5: Select a value for Import option:
If you already have an IoT hub in one of your subscriptions, select Use IoT Hub from available subscriptions. This option is the easiest approach.
Reference:
https://docs.microsoft.com/en-us/azure/time-series-insights/time-series-insights-how-to-add-an- event-source-iothub

QUESTION NO: 5
You need to configure Stream Analytics to meet the POV requirements.
What are two ways to achieve the goal? Each Answer presents a complete solution.
NOTE: Each correct selection is worth one point.
A. Route telemetry to an Azure Blob storage custom endpoint, and then configure the Blob storage as a reference input for Stream Analytics.
B. Create an input in Stream Analytics that uses the built-in events endpoint of IoT Hub as the source.
C. From IoT Hub, create a custom event hub endpoint, and then configure the endpoint as an input to Stream Analytics.
D. Create a Stream Analytics module, and then deploy the module to all IoT Edge devices in the fleet.
Answer: B,C
Explanation:

Microsoft AZ-104 - As you know, we are now facing very great competitive pressure. In order to save you a lot of installation troubles, we have carried out the online engine of the Snowflake COF-C02 latest exam guide which does not need to download and install. Let’s learn Network Appliance NS0-516 exam dumps, and you can pass the exam at once. Today, our SAP C_THR81_2405 exam materials will radically change this. Our Palo Alto Networks PSE-Strata real exam try to ensure that every customer is satisfied, which can be embodied in the convenient and quick refund process.

Updated: May 28, 2022