AZ-220 Review & Microsoft AZ-220 Training Topics - Microsoft Azure IoT Developer - Omgzlook

Our AZ-220 Review exam materials give real exam environment with multiple learning tools that allow you to do a selective study and will help you to get the job that you are looking for. Moreover, we also provide 100% money back guarantee on our AZ-220 Review exam materials, and you will be able to pass the AZ-220 Review exam in short time without facing any troubles. By clearing different Microsoft exams, you can easily land your dream job. If you are interested in Omgzlook's training program about Microsoft certification AZ-220 Review exam, you can first on Omgzlook to free download part of the exercises and answers about Microsoft certification AZ-220 Review exam as a free try. We will provide one year free update service for those customers who choose Omgzlook's products. Our AZ-220 Review exam questions zre up to date, and we provide user-friendly AZ-220 Review practice test software for the AZ-220 Review exam.

Microsoft Certified: Azure IoT Developer Specialty AZ-220 We can help you to achieve your goals.

With the help of our AZ-220 - Microsoft Azure IoT Developer Review practice materials, you can successfully pass the actual exam with might redoubled. But to succeed you can have a shortcut, as long as you make the right choice. I took advantage of Omgzlook's Microsoft AZ-220 Dumps Discount exam training materials, and passed the Microsoft AZ-220 Dumps Discount exam.

Compared with products from other companies, our AZ-220 Review practice materials are responsible in every aspect. After your purchase of our AZ-220 Review exam braindumps, the after sales services are considerate as well. We have considerate after sales services with genial staff.

Microsoft AZ-220 Review - Chance favors the prepared mind.

To ensure that you have a more comfortable experience before you choose to purchase our AZ-220 Review exam quiz, we provide you with a trial experience service. Once you decide to purchase our AZ-220 Review learning materials, we will also provide you with all-day service. If you have any questions, you can contact our specialists. We will provide you with thoughtful service. With our trusted service, our AZ-220 Review study guide will never make you disappointed.

We are ready to show you the most reliable AZ-220 Review pdf vce and the current exam information for your preparation of the test. Before you try to attend the AZ-220 Review practice exam, you need to look for best learning materials to easily understand the key points of AZ-220 Review exam prep.

AZ-220 PDF DEMO:

QUESTION NO: 1
Your company is creating a new camera security system that will use Azure IoT Hub.
You plan to use an Azure IoT Edge device that will run Ubuntu Server 18.04.
You need to configure the IoT Edge device.
Which three actions should you perform in sequence? To answer, move the appropriate actions from the list of actions to the answer area and arrange them in the correct order.
Answer:
Explanation:
Step 1: Run the following commands
Install the container runtime.
Azure IoT Edge relies on an OCI-compatible container runtime. For production scenarios, we recommended that you use the Moby-based engine provided below. The Moby engine is the only container engine officially supported with Azure IoT Edge. Docker CE/EE container images are compatible with the Moby runtime.
Install the Moby engine.
sudo apt-get install moby-engine
Install the Moby command-line interface (CLI). The CLI is useful for development but optional for production deployments.
sudo apt-get install moby-cli
Install the security daemon. The package is installed at /etc/iotedge/.
sudo apt-get install iotedge
Step 2: From IotHub,create an IoT Edge device registry entry.
Note: In your IoT Hub in the Azure portal, IoT Edge devices are created and managed separately from
IOT devices that are not edge enabled.
Sign in to the Azure portal and navigate to your IoT hub.
In the left pane, select IoT Edge from the menu.
Select Add an IoT Edge device.
Provide a descriptive device ID. Use the default settings to auto-generate authentication keys and connect the new device to your hub.
Select Save.
Retrieve the connection string in the Azure portal
1. When you're ready to set up your device, you need the connection string that links your physical device with its identity in the IoT hub.
2. From the IoT Edge page in the portal, click on the device ID from the list of IoT Edge devices.
3. Copy the value of either Primary Connection String or Secondary Connection String.
Step 3: Add the connection string to..
To manually provision a device, you need to provide it with a device connection string that you can create by registering a new device in your IoT hub.
Open the configuration file.
sudo nano /etc/iotedge/config.yaml
Find the provisioning configurations of the file and uncomment the Manual provisioning configuration section. Update the value of device_connection_string with the connection string from your IoT Edge device.
Save and close the file.
After entering the provisioning information in the configuration file, restart the daemon:
sudosystemctl restart iotedge
Reference:
https://docs.microsoft.com/en-us/azure/iot-edge/how-to-install-iot-edge-linux

QUESTION NO: 2
You have an Azure IoT hub that is being taken from prototype to production.
You plan to connect IoT devices to the IoT hub. The devices have hardware security modules (HSMs).
You need to use the most secure authentication method between the devices and the IoT hub.
Company policy prohibits the use of internally generated certificates.
Which authentication method should you use?
A. a symmetric key
B. An X.509 certificate signed by a root certification authority (CA).
C. an X.509 self-signed certificate
D. a certificate thumbprint
Answer: B
Explanation:
Purchase X.509 certificates from a root certificate authority (CA). This method is recommended for production environments.
The hardware security module, or HSM, is used for secure, hardware-based storage of device secrets, and is the most secure form of secret storage. Both X.509 certificates and SAS tokens can be stored in the HSM Reference:
https://docs.microsoft.com/en-us/azure/iot-dps/concepts-security

QUESTION NO: 3
You have an Azure IoT solution that includes an Azure IoT hub.
You receive a root certification authority (CA) certificate from the security department at your company.
You need to configure the IoT hub to use the root CA certificate.
Which four actions should you perform in sequence? To answer, move the appropriate actions from the list of actions to the answer area and arrange them in the correct order.
Answer:
Reference:
https://docs.microsoft.com/bs-latn-ba/azure/iot-hub/iot-hub-security-x509-get-started

QUESTION NO: 4
You have an instance of Azure Time Series Insights and an Azure IoT hub that receives streaming telemetry from IoT devices.
You need to configure Time Series Insights to receive telemetry from the devices.
Which three actions should you perform in sequence? To answer, move the appropriate actions from the list of actions to the answer area and arrange them in the correct order.
Answer:
Explanation:
Step 1: Create a dedicated consumer group..
Add a consumer group to your IoT hub.
Applications use consumer groups to pull data from Azure IoT Hub. To reliably read data from your
IoT hub, provide a dedicated consumer group that's used only by this Time Series Insights environment.
Step 2: Add a new Time Series Insights event source.
Add a new event source
Sign in to the Azure portal.
In the left menu, select All resources. Select your Time Series Insights environment.
Under Settings, select Event Sources, and then select Add.
In the New event source pane, for Event source name, enter a name that's unique to this Time Series
Insights environment. For example, enter event-stream.
Step 3: Configure the Time Series event source to connect to an existing IOT hub Step 4: For Source, select IoT Hub.
Step 5: Select a value for Import option:
If you already have an IoT hub in one of your subscriptions, select Use IoT Hub from available subscriptions. This option is the easiest approach.
Reference:
https://docs.microsoft.com/en-us/azure/time-series-insights/time-series-insights-how-to-add-an- event-source-iothub

QUESTION NO: 5
You need to configure Stream Analytics to meet the POV requirements.
What are two ways to achieve the goal? Each Answer presents a complete solution.
NOTE: Each correct selection is worth one point.
A. Route telemetry to an Azure Blob storage custom endpoint, and then configure the Blob storage as a reference input for Stream Analytics.
B. Create an input in Stream Analytics that uses the built-in events endpoint of IoT Hub as the source.
C. From IoT Hub, create a custom event hub endpoint, and then configure the endpoint as an input to Stream Analytics.
D. Create a Stream Analytics module, and then deploy the module to all IoT Edge devices in the fleet.
Answer: B,C
Explanation:

Our SAP C_LIXEA_2404 learning materials are new but increasingly popular choices these days which incorporate the newest information and the most professional knowledge of the practice exam. Passing HP HPE2-N71 practice exam is not so easy and need to spend much time to prepare the training materials, that's the reason that so many people need professional advice for HP HPE2-N71 exam prep. Dell D-PDPS-A-01 - If you have any questions about Microsoft Azure IoT Developer test torrent or there are any problems existing in the process of the refund you can contact us by mails or contact our online customer service personnel and we will reply and solve your doubts or questions promptly. The way to pass the Cisco 300-740 actual test is diverse. It is known to us that practicing the incorrect questions is very important for everyone, so our ISQI CTFL_Syll_4.0 exam question provide the automatic correcting system to help customers understand and correct the errors.

Updated: May 28, 2022